夜上海龙凤坊_深圳楼凤qm桑拿论坛_夜上海龙凤坊

Welcome to visit Xuzhou Youbo Electronic Technology Co., Ltd. Official website!

Mobile website

Official WeChat

Unified national service hotline

+86-0516-80301997

CONTACT US

  • More details, please call

    +86-0516-80301997

  • Online Message

    Online message

Company News

Location:Home > Industry news > Company News > Signal input characteristics of multi-function power meter
Signal input characteristics of multi-function power meter
Time:2018/10/29 13:44:00      hit count:921

The signal input of multifunctional power meter adopts the calculation method of separate collection of each measurement channel, which ensures the complete consistency and symmetry in use.

Signal input instructions of power meter:

Voltage input: the input voltage shall not be higher than the rated input voltage of the product (100V or 400V), otherwise PT should be considered, and 1A fuse should be installed at the input voltage.

Current input: the standard rated input current is 5A. If it is greater than 5A, external CT should be used. If the CT used is connected with other instruments, the connection shall be connected in series. Before removing the current input connection of the product, it is necessary to disconnect the primary CT circuit or the short-connected secondary circuit first. It is recommended to use wiring arrangement instead of direct connection with CT, so as to facilitate disassembly and assembly.

To ensure that the input voltage, current, phase sequence and direction are consistent; Otherwise, numerical and symbolic errors will occur. (power and electrical energy)

The configuration of the instrument input network is determined according to the number of CT in the system. In the case of 3 CT, select the three-phase four-line three-component mode. The input network NET set up in the connection of the meter and the programming of the meter should be the same as the connection mode of the load measured, otherwise the voltage or power measured by the meter will be incorrect. In the three-phase three-wire, the voltage measurement and display is the line voltage; In the three-phase four-wire, the voltage measurement shows the phase voltage.


News you are interested in
Previous:Signal input characteristics of multi-function power meter
Next:The temperature and humidity controller operates at high temperature

Back to list

主站蜘蛛池模板: 葫芦岛市| 牡丹江市| 潞西市| 水富县| 台中县| 桂平市| 休宁县| 清徐县| 新沂市| 鹰潭市| 长治市| 拜城县| 密山市| 鹤壁市| 江山市| 阿鲁科尔沁旗| 崇明县| 柳州市| 洪泽县| 开封市| 临泉县| 翁源县| 江西省| 胶州市| 来凤县| 彭水| 黔江区| 古丈县| 武城县| 三都| 阿荣旗| 天门市| 镇远县| 甘南县| 铜梁县| 体育| 东乡族自治县| 烟台市| 五峰| 惠安县| 安丘市|